East Coast Part Supplier and Warehouse Association Moderated Interchange Newsgroup   >   Virginia   >   Machinery   >   Fluke 1735 three-phase power logger

Fluke 1735 three-phase power logger


We are wholesaler and Distributor of all Electrical supplies brand name.
Email: ****@yahoo.com
If you need any assistants please call us.
We are representing whole line of fluke please call us if you need any special order.
For all Fluke products, there will be 5-7 business days lead time
Power quality logging, electrical load studies and energy consumption testing.
The Fluke 1735 Power Logger is the ideal electrician or technician’s power meter for conducting energy studies and basic power quality logging. Set the Power Logger up in seconds with the included flexible current probes and color display. The power quality meter measures most electrical power parameters, harmonics, and captures voltage events.
* Load studies - verify electrical system capacity before adding loads
* Energy assessments - quantify energy consumption before and after improvements to justify energy saving devices
* Harmonics measurements - uncover harmonic issues that can damage or disrupt critical equipment
* Voltage event capture - monitor for dips and swells that cause spurious resets or nuisance circuit breaker tripping
* Record power and associated parameters for up to 45 days
* Monitor maximum power demand over user-defined averaging periods
* Prove the benefit of efficiency improvements with energy consumption tests
* Measure harmonic distortion caused by electronic loads
* Improve reliability by capturing voltage dips and swells from load switching
* Easily confirm instrument setup with color display of waveforms and trends
* Measure all three phases and neutral with included 4 flexible current probes
* View graphs and generate reports with included Power Log software
* Compact, rugged design with IP65 case, 600 V CAT III and two-year warranty
¼ VGA Graphic Color transmissive displays 320 x 240 Pixel with additional background lighting and adjustable contrast, text and graphics in color
Developed, designed and manufactured according to DIN ISO 9001
4 MB Flash memory, 3.5 MB for measuring data
RS-232 SUB-D socket; 115.2 k Baud, 8 data bits, no parity, 1 stop bit, firmware updates are possible with the RS- 232 interface (9-pole extension cable)
50 Hz or 60 Hz, user-selectable, with automatic synchronization
NiMH battery-pack, with ac adapter (15 V to 20 V/0.8 A)
Typical > 12 hours without backlight and > 6 hours with backlight high
± 0.1 % of the measured value per °C from the reference
Refers to reference temperature, maximum deviation is guaranteed for two years
Refers to operating temperature range, maximum deviation is guaranteed for two years
C1 (IEC 654-1) -5 °C to +45 °C, 5% to 95% RH, no dew
Cycoloy shock and scratch proof thermoplast V0-type (non-flammable) with rubber protection holster
IEC 61010-1 600 V CAT III, double or reinforced insulation, pollution degree 2
IP65; EN60529 (refers only to the main housing without the battery compartment)
RMS values are measured with a 20 ms resolution
57 V/66 V/110 V/120 V/127 V/220 V/230 V/240 V/260 V/277 V/347 V/380 V/400 V/417 V/480 V ac
± (0.2% of measured value + 5 digits)
100 V/115 V/190 V/208 V/220 V/380 V/400 V/415 V/450 V/480 V/600 V/660 V/690 V/720 V/830 V ac
15 A/150 A/3000 A rms (at sine)
The errors of the current probes are not considered
When using Flexi Set please make sure to position the conductor opposite to the Flexi Set-lock
Power measurement (P - Active, S - Apparent, Q- reactive, D - Distorting
see V rms and A rms measurement
Power errors are calculated by adding the errors of voltage and current
Additional error due to power factor PF
Maximum range with voltage range 830 V delta-connection and 3000 A current range is 2.490 MW, higher displayed values possible when using PTs and CTs with ratio feature
Typical range with voltage range 230 V wye connection and 150 A current range is 34.50 KW.
The errors of the current sensors themselves have not been considered.
Energy measurement (kWh, KVAh, kVARh)
± (0.7 % of m.v.+ F variation error* + 15 digit)
± (1.5 % of m.v. + F variation error* + 20 digit)
46 Hz to 54 Hz and 56 Hz to 64 Hz
To 50th harmonic (< 50 % of nom)
Vm and Im are measured values of harmonic m
Detection of voltage dips, voltage swells and voltage interruptions with a 10 ms resolution and measuring error of the half period sine wave of rms.



Fluke 1735 three-phase power logger