A new member of the MFT family
The Megger MFT1553 is the latest version of the class-leading Megger multifunction testers with all the testing you need in one tough, easy to use, good value machine.
The new MFT1553 now allows you to transfer the test readings from the tester to a storage device wirelessly. When you have PowerSuite On-site, on your mobile device, like a smart-phone or a PDA, you can complete certificates as you go, there, on-site.
• Combined 16th Edition testing.
• Guaranteed non-tripping loop test range.
• Backlit display and selector ranges.
• Touch (fault) voltage and display.
• Calibrated earth loop test lead.
• Dimensions: 180 x 55 x 240mm.
• Weight: 1.5 kg with battery.
• Megger MFT 1553 Warranty: 3 year.
Megger MFT1553 User guide on CD, croc clips red, black & green, probes red & black, mains plug (BS1363) test lead, instument/document carry case, Illuminated switched probe & 3 wire test lead.
recommended price £995 plus vat
Cuthbertson Laird Group can supply all your test equipment needs.
sorry this item is not freepost
pFC MEASUREMENT ON BOTH LOOP TEST RANGES
SELECTABLE FAULT(TOUCH) VOLTAGE 25V TO 50V INHIBIT
Selecting the auto (RCD) feature, starts the RCD test current
Each time the RCD is tripped, resetting it, automatically
Once completed, test results can be recalled on the.
NON TRIPPING 0.01 OHM LOOP TEST
SUPPLY VOLTAGE AND POLARITY INDICATION
PHASE-PHASE,PHASE-NEUTRAL AND PHASE-EARTH LOOP TESTS
AC DC VOLTMETER+ - 280V AC/DC RANGE
200MA CONTINUITY FROM 0.01 OHM TO 99.9 OHM
VARABLE THRESHOLD IN 7 STEPS FROM 2OHM TO 200OHM
LEAD NULL STORAGE EVEN WHEN SWITCHED OFF
INSULATION TEST AT 250V,500V AND 1000V
TEST LEAD PANEL TO PREVENT HAZARDOUS LEAD COMBINATIONS
COLOUR CO-ORDINATED TEST BUTTONS
ILLUMINATED SWITCHED PROBE FOR SINGLE HANDED OPERATION
THREE INTERCHANGABLE PROBE TIPS= STANDARD SHROUDED,REMOVEABLE SHROUDED AND AN EXTENDED PROBE TIP.
PRICE INCLUDES CALIBRATION CERTIFICATE
The MFT1500 series uses the patented Megger digital/
analogue arc display. The analogue arc provides an
indication of fluctuating readings, while the digital readout
providing the ability to record accurate results.
All test functions are selectable from the main panel, with
no hidden ranges or functions to forget.
AC/DC Volt meter provides a means of measuring the
supply voltage independently of any other test functions,
eliminating the need to carry a separate multimeter.
Automatic selection of AC or DC measurement up to
200 mA continuity from 0.01 ½ to 99.9 k½ exceeds all
current requirements for testing final ring circuit
conductors, and bonding of services.
Automatic continuity testing commences the moment
the test probes touch the circuit to be tested, allowing
fast testing with both hands free.
Fast continuity buzzer is a fast buzzer tone, with no
delay on each test for the buzzer to sound, saving
valuable operator time. This test includes a fast safety
check for the presence of a voltage as the test probes
Guaranteed non-tripping loop test range
Backlit display and selector ranges
Automatic RCD testing (MFT1552 only)
Touch (fault) voltage and display
Calibrated earth loop test lead
Combined Insulation, Loop & RCD Tester
Combined Insulation, Loop & RCD Tester
Variable buzzer threshold controls the limit at which
the continuity buzzer stops sounding. Selected from 2
Lead null stores the test lead resistance and deducts this
value from the continuity result, even if the instrument is
switched off. Thus reducing the chance of possible
Insulation test at 250 V, 500 V and 1000 V for testing
low voltage applications. A 1000 V warning is issued
prior to performing the 1000 V insulation test.
Live circuit warning when performing insulation or
continuity measurements a live circuit warning is
displayed and an audible warning sounded if connected
to a circuit with a voltage greater than 25 V (15 V for
Safety lockout at voltages greater than 55 V during
continuity and insulation testing, the instrument
automatically warns the operator and inhibits any
testing, preventing accidental damage to the instrument
and full protection to the operator.
The ‘Auto discharge’ facility safely discharges all
circuits after an insulation test, preventing accidental
shock from a stored charge on a long cable during or
Low current loop test is a 3 wire non-tripping
½ loop test designed to prevent RCD tripping by
using a sophisticated 15 mA loop test pioneered by
Megger Limited. This NO-TRIP test ensures the RCD
trip whilst performing a loop impedance test.
High current loop test at 25 A provides a fast loop test
where no RCD is fitted, or for Ze measurement on the
Supply voltage and polarity indication upon
connection to the mains supply the polarity and voltage
are displayed to show correct wiring of the socket under
test or test lead connections. This function also provides
a warning of live voltages while continuity or insulation
Phase-Phase Phase-Neutral and Phase-Earth Loop Tests
are possible. No danger of damage from accidental 3-
Wide supply voltage; allows loop measurements from
55 V to 480 V. No damage if accidentally connected
Prospective short-circuit current (PSC) A dedicated
PSC range, using either the 25 A high current loop test or
no-trip test, is provided for rapid measurement of Loop
currents, both at the socket outlet and distribution
board. The PSC ranges from 1 A to 19.9 kA with a
resolution of 1 A, 10 A and 100 A depending on range. All
the loop and PSC tests are auto-ranging.
10 mA to 1000 mA RCD ranges. All standard RCDs
from 10 mA to 1000 mA are fully supported. All standard
RCD test functions are available with both 0° and 180°
RCD ramp test measures the RCD trip current. The
ramp test displays the actual trip current on all RCD
ranges instead of trip time. Ideal for identifying nuisance
tripping RCDs. The current is stepped up from
Fault (Touch) voltage can now be set for either 25 V or
50 V depending on application.
Fault/touch voltage can also be displayed up to 100 V on
DC sensitive, RCD test option enables testing at 1/2I,
Quick to pick up and use by using colour coded
ranges and no hidden functions the MFT1500 series takes
minutes to learn how to use. Function buttons are
colour matched to the test mode to ensure easy
Visible and audible Safety warning features are
paramount with live circuit warning and protection
circuitry. If live voltages exist on a circuit during
insulation or continuity testing the voltage is displayed
on the screen. If this voltage exceeds a safe level, the
MFT1500 series inhibits further testing and a warning
beeper sounds for extra safety.
Large easy-to-read LCD using the patented Megger
digital/analogue arc technology - combining high speed
analogue clarity with digital stability. Making it easy to
Economical with batteries by incorporates an auto
shut off facility that operates after 5 minutes of inactivity,
reducing wasted battery consumption.
Innovative test lead connection has been developed
for the MFT1500 series. The unique shutter system
allows only those combinations of test leads permitted
for safe testing to be connected. Unsafe or unnecessary
Rubber over-moulded case and lid. The ergonomic
rubber moulding provides a secure comfortable hold,
whilst providing maximum protection with IP54 weather
shines a new light on testing.
A fully featured test probe allows for single-handed
operation and test status indication. Probe features include:
Remote test button for single-handed testing in difficult
locations, the test button duplicates the instrument test
Combined Insulation, Loop & RCD Tester
LED torch using a built-in WHITE LED light provides illumination
to the probe tip, providing essential lighting in
Red/green status LED duplicates the warning display on
the main instrument display. A RED LED indicates a
voltage present on an insulation range. A GREEN LED
indicates the instrument is displaying a valid test result.
Three interchangeable probe tips are supplied in
standard shrouded, removable shrouded and an extended
probe tip to provides the ideal probe tip option.
Illuminated display and selector ranges. Not only the
backlight, but also the selector dials are illuminated to
allow for use in difficult low-light conditions. Range or
function change automatically operates the backlight, or
Instrument and document carry case is supplied to
transport the instrument as well as any necessary test
leads, documents, drawings etc.
Selecting the auto (RCD) feature, starts the RCD test current
Each time the RCD is tripped, resetting it, automatically
Once completed, test results can be recalled on the
0 V - 500 V 50/60Hz ±2% ±2 digits
Insulation test ranges (to EN 61557-2)
250, 500 and 1 kV into 1 mA (BS7671, HD384 and IEC364)
+20% - 0% at rated load or less
55 V visual, audible and test inhibit
>280 V visual, audible and test inhibit
½, 5 ½, 10 ½, 20 ½, 50 ½, 100 ½
Open circuit voltage 4-5 V d.c.
Loop test ranges (to EN 61557-3)
½ - 2.00 k½ (±5% ±0.03 ohms ± Noise Margin).
Prospective Shortcircuit Current PSC
Prospective fault current = Nominal Voltage/Loop Resistance
Accuracy is therefore derived from the loop test.
0.02 kA - 1.99 kA 10 A resolution
2.0 kA - 19.9 kA 100 A resolution
1000 mA, 500 mA, 300 mA, 100 mA, 30 mA, 10 mA
1/2I - 1/2 times the selected RCD rated current.
- One times selected RCD rated current.
- Five times I RCD rated current.
- A ramp test that displays actual trip current .
- A DC test current at 1/2I, I and 5I.
Multifunction tester with automatic RCD testing MFT1552
Megger is a registered trademark
Touch (Fault) voltage: 0 V to 100 V error ±5% to +15% ±0.5 V
8 x 1.5 V Alkaline cells type LR6
Replaceable 500 mA (F) HBC 10 kA 500 V
Non-replaceable 7 A (SIBA 70-065-63) x 2
CLASS 1 LED to IEC 60825:2001 Interchangeable tips
1 x 9 V Alkaline cell type PP3
Non-replaceable 7 A (SIBA 70-065-63)
Double insulated to IEC61010-1-2001, Installation Category III,
300 V phase to earth, 500 V phase to phase.
In addition Probe designed to meet IEC 61(***)-031-2002, Double
insulated to Installation Category III, 300 V phase to earth, 500 V
In accordance with IEC 61326 including amendment No. 1
Dust and water protection: Instrument IP54, probe no rating
150 mm high x 85 mm wide x 235 mm deep
Complies with the following parts of 61557, electrical safety in
low voltage systems up to 1000 V a.c. and 1500 V d.c.-
Equipment for testing, measuring or monitoring of protective
Part 6- Residual current devices (RCD)
Part 10- Combined measuring equipment
remember this is brand new and comes with calibration cert,3 year megger warrantee and a hard carry case



New MFT1553 megger mft 1553 with bluetooth